Onderwerp: Bezoek-historie

1069 Interpretation of SOLAS regulation XII/13
Geldigheid:06-12-2003 t/m Status: Geldig vandaag

Dit onderwerp bevat de volgende rubrieken.

Interpretation of SOLAS regulation XII/13

  1. The Maritime Safety Committee, at its seventy-seventh session (28 May to 6 June 2003),
    having considered a recommendation made by the Sub-Committee on Ship Design and Equipment at
    its forty-sixth session, and agreeing that there was a need to ensure uniformity in the application of
    SOLAS regulation XII/13 - Availability of pumping systems, as well as consistency with SOLAS
    regulation XII/12 - Hold, ballast and dry space water level detectors, approved an interpretation of
    the said regulation, as set out in the annex.

  2. Member Governments are invited to use the annexed interpretation when applying the
    provisions of SOLAS regulation XII/13, and to bring it to the attention of all parties concerned.

Annex Spaces where availability of pumping systems is required

Spaces where availability of pumping systems prescribed in paragraph 1 of SOLAS regulation XII/13 is required

  1. The spaces where availability of pumping systems is required in accordance with paragraph 1 of SOLAS regulation XII/13 should be the same watertight spaces where water level detectors are required in accordance with paragraph 1.3 of SOLAS regulation XII/12.

  2. This means that paragraph 1 of regulation XII/13 does not apply to the enclosed spaces the volume of which does not exceed 0.1% of the ship's maximum displacement volume and to the chain cable locker.