INTERNATIONA L  MRIITIME    ORGANIZATION 

4ALBERTEMBANKMENT LONDONSE17SR                         

 

 

                                                        

                                                                                 

                                                                                                                                                

 

 

 

Telephone:  0171-7357611

 

 

Fax:

0171-5873210

 

Telex:

23588IMOLDNG

                                     IMO

 

 

                  

 

                                                                                  

      Ref. T5/1.01                                                                                                                   MEPC/Circ.363

 

                                                                                                                                                                                              26July1999

 

 

       

 

 

                                                                        TANK CLEANING ADDITIVES GUIDANCE NOTE

 

 

ANDREPORTINGFORMFORTHE SUBMISSIONOF TANKCLEANINGADDITIVESDATA

 

 

 

 

 

1          TheMarineEnvironmentProtectionCommittee,atitsthirty-thirdsession,adoptedamendmentstothe StandardsforProceduresandArrangementsfortheDischargeofNoxiousLiquidSubstanceswhichincluded restrictiononthetypesofdetergentsusedintankwashingasfollows:

 

 

“1.8.2   Whensmallamountsofdetergentsareaddedtowaterinordertofacilitatetankwashing,no detergents containing pollution category A components should be used except those componentsthatarereadilybiodegradableandpresentinatotalconcentrationoflessthan

 

10%.   Norestrictionsadditionaltothoseapplicabletothetankduetothepreviouscargo shouldapply.”

 

 

2          TheCommittee,atitsthirty-seventhsession,notedthattherewereproblemsinapplyingtheGuidelines

 

fortheEvaluationoftheHazardsofCleaningAgentsasdevelopedbytheSub-CommitteeonBulkChemicals

 

(BCH24/15,annex5)andsoauthorizedtheirrevision.

 

 

3          TheCommittee,atitsforty-thirdsession,approvedtherevisedGuidelineswhichincludesaguidance noteandproductreportingFormforthesubmissionofdataontheevaluationofcargotankcleaningadditives.

 

 

4          Member Governments are invited to bring this information to the attention of those companies submittingdataontankcleaningadditivestotheBLGSub-Committeeinordertodeterminewhethertheymeet

 

therequirementsofparagraph1.8.2oftheProceduresandArrangementsStandards.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.1 REPORTING FORM FOR THE SUBMISSION OF DATA FOR THE EVALUATION OF CARGO TANK CLEANING ADDITIVES

 

Par t A .             ConfidentialData

 

 

Proprietar y dat a wil l b e treate d a s confidentia l b y th e nationa l Administration s an d their representative s whic h for m th e evaluatin g grou p withi n IMO .  Continuationsheetsmay

 

b e use d a s needed.

 

 

Nam e o f producin g compan y              : Productname                                                           :

 

 

(astheyaretoappearinlistofTankCleaningAdditivesmeetingtheIMOguidelines)

 

 

Component

 

No.

Componen t name

CA S No.

Weight

 

%

GESAMP

 

Hazard

 

Profile

IMO

 

Pollution

 

Category

1

 

 

 

 

 

2

 

 

 

 

 

3

 

 

 

 

 

4

 

 

 

 

 

5

 

 

 

 

 

6

 

 

 

 

 

7

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

Intende d us e o f th e product

 

 

Typicalrateofdilutioninwashwaterrequiredforproperuseoftheproduct:                 %

 

(asstatedbythemanufacturerinthedescriptionofuse)

 

 

ATTACHPRODUCTSPECIFICATIONS/USAGEINSTRUCTIONS*

 

 

 

 

 

 

 

 

Tobeusedasacargotankcleaningadditive:                          yes /no(omit if not applicable)

 

 

 

 

 

 

 

 

 

 

 

 

 

*This information does not restrict the use of this additive by a purchaser for other purposes.

 


 

 

 

Par t B . Required information on components

 

 

·            IfcategoryAcomponentsareinvolved,thenbiodegradationdatashouldbesupplied below.

 

·            IfproductshavenotyetbeenevaluatedbyGESAMP,thenallinformationrequested belowshouldbeprovidedforeachcomponent.

 

 

ECOTOXICITY

Componen t   No.

Tes t   species

LC50   in   mg   /   l

Tes t   method

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BIODEGRADATION

Componen t   No.

Tes t   method

%   degradatio n   i n   2 8   days

 

 

 

 

 

 

 

 

 

Componen t No.

Tes t o r calculatio n method

Lo g Po w / BCF

 

 

 

 

 

 

 

 

 

 

 

Dat e :                           SignatureandTitle:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ANNEX

 

 

 

 

TAN K CLEANIN G ADDITIVE S    GUIDANC E NOT E AN D REPORTIN G FOR M FO R THE SUBMISSIO N O F TAN K CLEANIN G ADDITIVE S DATA

 

 

 

INTRODUCTION

 

 

Atankcleaningadditiveisaproductusedforthecleaningofcargotanksandassociatedpipingsystemson shipscarryingnoxiousliquidsubstancesandisusedbyaddingittothewashwaterinsmallamounts.

 

 

TheuseofcleaningadditivesmustberecordedintheCargoRecordBookasstatedinAppendixIVtoAnnex

 

IIofMARPOL73/78,"Listofitemstoberecorded,"(E)15.2.

 

 

TankcleaningadditivesareevaluatedbytheSub-CommitteeonBulkLiquidsandGases(BLG)inorderto protectthemarineenvironmentfromadverseeffectsrelatedtotheiruse.

 

 

Itisnottheintentionoftheevaluationtodeterminetheefficacyoftheproducts,butrathertodeterminetheir environmentalacceptability.

 

 

Thisdocumentcontainsaguidancenoteandaformtofacilitatethesubmissionofdatabymanufacturers. This

 

isintendedtoeasetheprocessofevaluationoftankcleaningadditives.

 

 

Paragraph1.8.2oftheStandardsforProceduresandArrangementsunderAnnexIIofMARPOL73/78, formsthebasisuponwhichcleaningadditivesareevaluated. Itreadsasfollows:

 

 

"Whensmallamountsofcleaningdetergentsareaddedtowaterinordertofacilitatetank washing,nodetergentscontainingpollutioncategoryAcomponentsshouldbeusedexcept thosecomponentsthatarereadilybiodegradableandpresentinatotalconcentrationofless than10%.  Norestrictionsadditionaltothoseapplicabletothetankduetothepreviouscargo shouldapply."

 

 

GUIDANC E NOTE

 

 

1          The composition of the product should be fully specified, given that tank cleaning additives are evaluatedonthebasisofanyindividualingredient.   Componentswhichhaveoneorbothofthefollowing characteristicsshouldnotbeusedintankcleaningadditiveformulations:

 

 

.1         Componentswhicharepersistentandbioaccumulatingtoasignificantextentandknownto produceahazardtoaquaticlifeorhumanhealth.

 

 

.2         Components which are severely toxic to marine life, i.e. those having an LC50 value

 

of0.1ppmorless.

 

 

2          IfactiveingredientsincludepollutioncategoryAsubstances(accordingtotheIBCCode,GESAMP Hazard Profile or provisional assessment), test data for ready biodegradability must be provided.   The proportionofsuchingredientsmustbelessthan10%ofthetotalproductforthetankcleaningadditivetobe accepted. Substancesnotpreviouslyassessedmustbetestedforreadybiodegradability,aquatictoxicityand bioaccumulation. Forcomponentsthathavenotbeenevaluatedpreviouslybytheabove-mentionedbodies, aquatictoxicityshouldbeinvestigatedfirst. Ifshowntobebelow1mg/l,thecomponentshouldthenbe testedforreadybiodegradability.

 

 

 

 

 


 

 

.1         AcuteAquaticToxicityData

 

 

ThetestproceduresforaquatictoxicitysuchasOECD203,itsISOorotherequivalents, shouldbeusedforsolublesubstances.   Forsubstancesoflowsolubility,Annex9ofIMO GESAMP Reports and Studies No. 35 should be followed.                                                     A marine or fresh water crustacean is considered to be suitable for such testing purposes (e.g., Daphnia magna, Mysidopsisbahia,ChaetogammarusmarinusandAcartiatonsa).   Existingdataonfishor crustaceanswouldbeacceptableforassessment.

 

 

.2         BiodegradabilityData

 

 

Thepreferredtestisa28dayreadybiodegradabilitytestsimilartoOECD301AtoE,itsISO

 

orotherequivalents.

 

 

.3         TheLogOctanolWaterPartitionCoefficient

 

 

Thiscoefficient(Log Pow) is a predictive measure of the tendency of a substance to accumulate in the fatty tissues of an organism.                           It can be measured using OECD Guidelines107or117,itsISOorotherequivalents,oralternativelyitcanbecalculatedusing fragmentalconstants(QSAR). Ifavailable,measuredbioconcentrationdataarepreferred.

 

 

3          IfactiveingredientsincludesubstancesinpollutioncategoryB,C,DorappendixIII(accordingtothe IBC Code, GESAMP Hazard Profile or provisional assessment) the component would be acceptable. Unevaluatedcomponentswouldbeacceptable,providedtheacutetoxicityis>1mg/l.

 

 

4          ComponentsthatareconsideredeitherAnnexIorpetrochemicalcomplexmixturesofhydrocarbons willbeevaluatedusingtheprocedureoutlinedinMEPC/Circ.265,basedontheprovisionalassessmentof hydrocarbonfamilies.

 

 

5          Thefollowingproceduresforsubmissionofnewcleaningadditivesareapplicable:

 

 

.1         DataonproductstobeevaluatedbyIMOshouldbemadeavailabletothenational

 

Administrationinvolved,bymeansoftheaccompanyingform.

 

 

.2         Thecomponentnamesusedontheformshallbethecorrecttechnicalnames,which meansthattradenamesarenotacceptable. Anytradenamedcomponentsmusthave theiringredientsandtheirproportionsfullyspecified.

 

 

.3         ThedatashallbesubmittedataperiodpriortotherelevantIMOmeeting,whichis acceptabletothenationalAdministrationinvolved.

 

 

.4         Incompletedatawillnotbetakenintoconsideration.

 

 

.5         AllproprietarydatawillbetreatedasconfidentialbythenationalAdministrationsand theirrepresentatives,whichformtheevaluatinggroup.

 

 

.6         Anychangesinnames,compositionorotherwiseofanyproductwhichhaspassed the evaluation of IMO at an earlier occasion, shall be reported to the national Administration.

 

 

 

 

 