Onderwerp: Bezoek-historie

952(23) Graphical symbols for shipboard fire control plans
Geldigheid:01-01-2004 t/m Status: Geldig vandaag

Dit onderwerp bevat de volgende rubrieken.

Graphical symbols for shipboard fire control plans

  dd-mm-yyyy = Entry into force
DocumentA. Resolution A.952(23)

AGREES that ships constructed before 1 January 2004 may continue to carry fire control plans that use the graphical symbols contained in resolution A.654(16);

05-12-2003

A. Resolution A.654(16)

19-10-1989


THE ASSEMBLY,

RECALLING Article 15(i) of the Convention on the International Maritime Organization concerning the functions of the Assembly in relation to regulations and guidelines concerning maritime safety,

BEARING IN MIND that regulation II-2/15.2.4 of the International Convention for the Safety of Life at Sea (SOLAS), 1974, as amended, requires that fire control plans be permanently exhibited for the guidance of the ship.s officers and that a duplicate set of fire control plans or a booklet containing such plans be permanently stored in a prominently marked weathertight enclosure outside the deckhouse for the assistance of shore-side fire-fighting personnel,

RECOGNIZING that the use of international symbols for shipboard fire control plans would greatly increase their usefulness, both for the crew of the ship and for shore-based fire brigades,

RECALLING ALSO resolution A.654(16) on Graphical symbols for fire control plans,

NOTING that ISO had, in close co-operation with IMO, developed standard ISO 17631:2002 . Ships and marine technology . Shipboard plans for fire protection, life-saving appliances and means of escape, providing fire protection symbols which generally conform to the corresponding symbols set out in resolution A.654(16),

NOTING IN PARTICULAR that, through MSC/Circ.1050, Member Governments had been invited to bring standard ISO 17631:2002 to the attention of shipbuilders, shipowners, shipoperators, shipmasters, shore-based fire-fighting personnel and other parties concerned with the preparation or use of shipboard fire control plans, so that they might use it, on a voluntary basis, for the preparation or use of the shipboard fire control plans required by SOLAS regulation II-2/15.2.4, pending the outcome of the work related to the revision of resolution A.654(16),

HAVING CONSIDERED the recommendation made by the Maritime Safety Committee at its seventy-seventh session,

  1. ADOPTS the Graphical symbols for shipboard fire control plans, set out in the Annex to the present resolution;

  2. URGES Governments to bring the aforementioned graphical symbols to the attention of shipbuilders, shipowners, shipoperators, shipmasters, shore-based fire-fighting personnel and other parties concerned with the preparation or use of shipboard fire control plans with a view to encouraging their use for the preparation of the shipboard fire control plans required by SOLAS regulation II-2/15.2.4, for ships constructed on or after 1 January 2004;

  3. INVITES Governments to bring standard ISO 17631:2002 to the attention of shipbuilders, shipowners, shipoperators and shipmasters so that they may use the additional guidance contained therein for the preparation of shipboard fire control plans;

  4. AGREES that ships constructed before 1 January 2004 may continue to carry fire control plans that use the graphical symbols contained in resolution A.654(16);

  5. REQUESTS the Maritime Safety Committee to keep this resolution under review and to amend it as necessary.

Annex

A legend of symbols and explanations should be a constituent part of any fire control plan and contain a list of the graphical symbols used in the plan, together with the appropriate explanations, and may include additional special information such as the type of extinguishing media used in fixed fire-extinguishing systems.

01 Graphical symbols for structural fire protection

No.Graphical symbolReferenceComments on use
1.1A-class division 
1.2B-class division 
1.3Main vertical zone 
1.4A-class hinged fire doorThe symbol should be at the door position and should show the actual direction of the door

Add WT to the right side of the symbol in case of a watertigth door.

Add SWT to the right side of the symbol in case of a semi-watertight door
1.5B-class hinged fire doorThe symbol should be at the door position and should show the actual direction of the door

Add WT to the right side of the symbol in case of a watertigth door.

Add SWT to the right side of the symbol in case of a semi-watertight door
1.6A-class hinged self-closing fire doorThe symbol should be at the door position and should show the actual direction of the door

Add WT to the right side of the symbol in case of a watertigth door.

Add SWT to the right side of the symbol in case of a semi-watertight door
1.7B-class hinged self-closing fire doorThe symbol should be at the door position and should show the actual direction of the door

Add WT to the right side of the symbol in case of a watertigth door.

Add SWT to the right side of the symbol in case of a semi-watertight door
1.8A-class sliding fire doorThe symbol should be at the door position and should show the actual direction of the door

Add WT to the right side of the symbol in case of a watertigth door.

Add SWT to the right side of the symbol in case of a semi-watertight door
1.9B-class sliding fire doorThe symbol should be at the door position and should show the actual direction of the door

Add WT to the right side of the symbol in case of a watertigth door.

Add SWT to the right side of the symbol in case of a semi-watertight door
1.10A-class slef-closing sliding fire doorThe symbol should be at the door position and should show the actual direction of the door

Add WT to the right side of the symbol in case of a watertigth door.

Add SWT to the right side of the symbol in case of a semi-watertight door
1.11B-class self-closing fire doorThe symbol should be at the door position and should show the actual direction of the door

Add WT to the right side of the symbol in case of a watertigth door.

Add SWT to the right side of the symbol in case of a semi-watertight door
1.12Ventilation remote control or shut-offColour of the circle and a letter at the right side of the symbol should indicate as follows

A = blue for accomodation and service spaces;

M = green for machinery

C = yellow for cargo spaces
1.13Remote control for skylight 
1.14Remote control for watertight doors or fire doorsAdd WT to the right side of the symbol to indicate remote control for watertight doors or FD to indicate remote control for fire doors
1.15Fire damperColour of the circle and a letter at the right side of the symbol should indicate as follows

A = blue for accomodation and service spaces;

M = green for machinery

C = yellow for cargo spaces

Identification number of the damper may be shown at the bottom of the symbol
1.16Closing device for ventilation inlet or outletColour of the circle and a letter at the right side of the symbol should indicate as follows

A = blue for accomodation and service spaces;

M = green for machinery

C = yellow for cargo spaces

Identification number of the damper may be shown at the bottom of the symbol
1.17Remote control for fire dampersColour of the circle and a letter at the right side of the symbol should indicate as follows

A = blue for accomodation and service spaces;

M = green for machinery

C = yellow for cargo spaces

Identification number of the damper may be shown at the bottom of the symbol
1.18Remote control for closing device(s) for ventilation inlet and outletColour of the circle and a letter at the right side of the symbol should indicate as follows

A = blue for accomodation and service spaces;

M = green for machinery

C = yellow for cargo spaces

Identification number of the damper may be shown at the bottom of the symbol

02 Graphical symbols for fire-protection appliances

No.Graphical symbolReferenceComments on use
2.1Fire protection appliances or structural fire protection plan 
2.2Remote control for fire pump(s) 
2.3Fire pump(s)The type, quantity of water delivered per time unit, and pressure head should be indicated either at the right side of the symbol or in the legend
2.4Remote control for emergency fire pump or fire pump supplied by the emergency source of power 
2.5Emergency fire pumpThe type, quantity of water delivered per time unit, and pressure head should be indicated either at the right side of the symbol or in the legend
2.6Fuel pump(s) remote shut-off 
2.7Lube oil pump(s) remote shut-off 
2.8Remote control for bilge pump(s) 
2.9Remote control for emergency bilge pump 
2.10Remote control for fuel oil valves 
2.11Remote control for lube oil valves 
2.12Remote control for fire pump valve(s) 
2.13Remote release station Indicate at the bottom of the symbol the protected space. Extinguishing media should be colour coded in the lower part of the symbol and be indicated by a letter at the right side of the symbol as follows:

grey - CO2 for carbon dioxide or N for nitrogen, brown - H for gas other than CO2 or N (type of gas to be indicated), white - P for powder, green - W for water.
2.14International shore connection 
2.15Fire hydrant 
2.16Fire main section valveIndicate the reference number of the valve at the right side of the symbol.
2.17Sprinkler section valve Indicate the reference number of the valve at the right side of the symbol.

This symbol may also be applied to equivalent water-extinguishing systems.

Valves for automatic dry-pipe sprinkler systems should be indicated in the legend.
2.18Powder section valveIndicate the reference number of the valve at the right side of the symbol.
2.19Foam section valveIndicate the reference number of the valve at the right side of the symbol.
2.20Fixed fire-extinguishing installation Extinguishing media should be colour- coded in the centre part of the symbol and indicated by a letter on top of the symbol as follows: grey - CO2 for carbon dioxide or N for nitrogen, yellow - F for foam, brown - H for gas other than CO2 or N (type of gas to be indicated), white - P for powder, green - W for water.
2.21Fixed fire-extinguishing batteryExtinguishing media should be colour- coded in the lower part of the symbol and indicated by a letter on top of the symbol as follows: grey - CO2 for carbon dioxide or N for nitrogen, yellow - F for foam, brown - H for gas other than CO2 or N (type of gas to be indicated), white - P for powder, green - W for water.
2.22Fixed fire-extinguishing bottle, placed in a proctected areaExtinguishing media should be colour- coded in the centre part of the symbol and indicated by a letter on top of the symbol as follows: grey - CO2 for carbon dioxide or N for nitrogen, yellow - F for foam, brown - H for gas other than CO2 or N (type of gas to be indicated), white - P for powder, green - W for water.
2.23High expansion foam supply trunk (outlet)Indicate at the bottom of the symbol the protected space, if necessary
2.24Water spray system valvesIndicate at the bottom of the symbol the protected space, if necessary
2.25Inert gas installation 
2.26MonitorExtinguishing media should be colour-coded in the centre part of the symbol and indicated by a letter on the right side of the symbol as follows: yellow - F for foam, white - P for powder, green - W for water.
2.27Fire hose and nozzleIndicate the hose length at the right side of the symbol; where only one type of hose is used, the information can be shown in the legend. Extinguishing media should be colour-coded in the lower part of the symbol and indicated by a letter on the right side of the symbol as follows: yellow .-F for foam, white - P for powder, green - W for water.
2.28Fire extinguisherIndicate type of extinguishing media (CO2 for carbon dioxide, F for foam, H for gas other than CO2 (type of gas to be indicated), P for powder, W for water) and capacity (kg for gas and powder, litres for water and foam) at the right side of the symbol. Media should be colour-coded in the lower part of the symbol as follows: grey for carbon dioxide, yellow for foam, brown for gas other than CO2, white for powder, green for water.
2.29Wheeled fire extinguisherIndicate type of extinguishing media (CO2 for carbon dioxide, F for foam, H for gas other than CO2 (type of gas to be indicated), P for powder, W for water) and capacity (kg for gas and powder, litres for water and foam) at the right side of the symbol. Media should be colour-coded in the centre part of the symbol as follows: grey for carbon dioxide, yellow for foam, brown for gas other than CO2, white for powder, green for water.
2.30Portable foam applicator unit o relevant spare tank(s) 
2.31Fire lockerIndicate the number of the fire locker at the right side of the symbol. The principal contents of each fire locker should be indicated in the legend.
2.32Space or group of spaces protected by fire-extinghuising systemIndicate type of extinguishing media (CO2 for carbon dioxide, F for foam, H for gas other than CO2 (type of gas to be indicated), P for powder, W for water, S for sprinkler or high pressure water extinguishing system) and capacity (kg for gas and powder, litres for water and foam) at the top of the symbol. Add suffix .L. for fixed local application fire fighting system. Media should be colour-coded in the symbol as follows: grey for carbon dioxide, yellow for foam, brown for gas other than CO2, white for powder, green for water, orange for sprinkler or high pressure water extinguishing system.
2.33Water fog applicator 
2.34Emergency source of electrical power (generator) 
2.35Emergency source of electrical powr (battery) 
2.36Emergency switchboard 
2.37Air compressor for breathing devices 
2.38Control panel for fire detection and alarm system 
2.39Push button/switch for general alarm 
2.40Manually operated call pointThe use of this symbol is optional at the discretion of the competent authority.
2.41Space or group of spaces monitored by smoke detector(s)The space(s) should be identified.
2.42Space or group of spaces monitored by heat detector(s)The space(s) should be identified.
2.43Space or group of spaces monitored by flame detector(s)The space(s) should be identified.
2.44Space monitored by gas detector(s) 

03 Graphical symbols for means of escape and escape-related devices

No.Graphical symbolReferenceComment on use
3.1Primary escape route 
3.2Secondary escape route 
3.3Emergency escape breathing device (EEBD)Indicate the quantity of the EEBDs stowed at the right side of the symbol.